The EFDR series skirt-mounted battery thermal management unit can be flexibly arranged (on chassis or frame) and its height is consistent with that of mainstream batteries. It is applied to various battery swapping/charging heavy-duty trucks, pure electric sanitation vehicles, construction machinery, and more. The unit features an aluminum alloy frame structure for weight reduction and efficiency improvement.It can be optionally equipped with a PTC liquid heater and has standby, cooling, heating, and self-circulation working modes.It uses CAN bus communication, has fault self-diagnosis capabilities, and can upload real-time operating status and fault information.Its EMC meets the requirements of Level III.

CLING EFDR Series Independent Battery Thermal Management Unit
Features
CLING EFDR Series Independent Battery Thermal Management Unit

Product specification 

The single-system cooling capacity ranges from 3kw to 13kw, while the dual-system cooling capacity can reach up to 20kw.

CLING EFDR Series Independent Battery Thermal Management Unit

Wide Product Applicability

To meet the diverse application scenarios of new energy trucks and construction machinery, we have developed thermal management units that can still cool at -40℃ and operate reliably at 60℃. We also provide solutions for applications under harsh road conditions, high dust, and high corrosion environments.

CLING EFDR Series Independent Battery Thermal Management Unit

Full-process customization services

We offer comprehensive solutions for thermal management systems based on customer needs. We not only provide thermal management units but also offer full-process services, including system design, installation, and maintenance.





Technical Parameters
EFDR-01
EFDR-02
EFDR-03
EFDR-04
EFDR-05
Model EFDR-01
Customized Cooling Capacity 2600 kcal/h
3 kW
10200 BTU/h
Unit Energy Efficiency 2.2
Unit Operating Temperature Range (℃) -20~60
Low Voltage Demand Power (W) 450
High Voltage Power Supply DC600V (400~750)
Low Voltage Power Supply DC24V (18-32)
Water Pump (Built-in) (W) 100
Overall Protection Level IPX7
Refrigerant R1234yf / R134a
Refrigerating Medium Type 50%VV Ethylene Glycol Aqueous Solution
Overall Dimensions (mm) LxWxH 685*600*280
Joint Flange/pier head ( Φ25) / Customizable
Connector Aviation plug-in / AMP
Low Voltage Power Distribution DC-DC included in the unit / Vehicle supply
Heating Function Reserve 5kW/10kW/14kW/24kW for selection


Model EFDR-02
Customized Cooling Capacity 4300 kcal/h
5 kW
17000 BTU/h
Unit Energy Efficiency 2.2
Unit Operating Temperature Range (℃) -20~60
Low Voltage Demand Power (W) 800
High Voltage Power Supply DC600V (400~750)
Low Voltage Power Supply DC24V (18-32)
Water Pump (Built-in) (W) 180
Overall Protection Level IPX7
Refrigerant R1234yf / R134a
Refrigerating Medium Type 50%VV Ethylene Glycol Aqueous Solution
Overall Dimensions (mm) LxWxH 685*600*280
Joint Flange/pier head ( Φ25) / Customizable
Connector Aviation plug-in / AMP
Low Voltage Power Distribution DC-DC included in the unit / Vehicle supply
Heating Function Reserve 5kW/10kW/14kW/24kW for selection


Model EFDR-03
Customized Cooling Capacity 6850 kcal/h
8 kW
27300 BTU/h
Unit Energy Efficiency 2.2
Unit Operating Temperature Range (℃) -20~60
Low Voltage Demand Power (W) 800
High Voltage Power Supply DC600V (400~750)
Low Voltage Power Supply DC24V (18-32)
Water Pump (Built-in) (W) 240
Overall Protection Level IPX7
Refrigerant R1234yf / R134a
Refrigerating Medium Type 50%VV Ethylene Glycol Aqueous Solution
Overall Dimensions (mm) LxWxH 818*600*280
Joint Flange/pier head ( Φ25) / Customizable
Connector Aviation plug-in / AMP
Low Voltage Power Distribution DC-DC included in the unit / Vehicle supply
Heating Function Reserve 5kW/10kW/14kW/24kW for selection


Model EFDR-04
Customized Cooling Capacity 8600 kcal/h
10 kW
34000 BTU/h
Unit Energy Efficiency 2.2
Unit Operating Temperature Range (℃) -20~60
Low Voltage Demand Power (W) 1000
High Voltage Power Supply DC600V (400~750)
Low Voltage Power Supply DC24V (18-32)
Water Pump (Built-in) (W) 240
Overall Protection Level IPX7
Refrigerant R1234yf / R134a
Refrigerating Medium Type 50%VV Ethylene Glycol Aqueous Solution
Overall Dimensions (mm) LxWxH 1005*557*280
Joint Flange/pier head ( Φ25) / Customizable
Connector Aviation plug-in / AMP
Low Voltage Power Distribution DC-DC included in the unit / Vehicle supply
Heating Function Reserve 5kW/10kW/14kW/24kW for selection


Model EFDR-05
Customized Cooling Capacity 13kw
Unit Energy Efficiency 2.2
Unit Operating Temperature Range (℃) -20~60
Low Voltage Demand Power (W) 2000
High Voltage Power Supply DC600V (400~750)
Low Voltage Power Supply DC24V (18-32)
Water Pump (Built-in) (W) 400
Overall Protection Level IPX7
Refrigerant R1234yf / R134a
Refrigerating Medium Type 50%VV Ethylene Glycol Aqueous Solution
Overall Dimensions (mm) LxWxH 1200*900*650
Joint Flange/pier head ( Φ25) / Customizable
Connector Aviation plug-in / AMP
Low Voltage Power Distribution DC-DC included in the unit / Vehicle supply
Heating Function Reserve 5kW/10kW/14kW/24kW for selection